What really distinguishes an enhanced monofocal lens from a standard monofocal lens: three optical strategies, what the optical bench and the meta-analyses show about intermediate vision, contrast and photic phenomena, how the pupil and corneal SA change the picture, and what to tell the patient.

In brief

  • “Monofocal plus” (enhanced monofocal) is a name for several different optical strategies: a central power add with higher-order asphericity, negative SA or positive SA. What they have in common is a single focus that is slightly stretched.
  • In meta-analyses, compared with a standard monofocal: intermediate acuity better by about 0.1 logMAR (about one line), the same distance vision, and no difference in contrast sensitivity or photic phenomena. Most of the evidence is on a single model.
  • The models do not meet the ANSI definition of EDOF, and in a meta-analysis of defocus curves their range is almost identical to that of a monofocal.
  • The gain depends on the pupil, the lens power and corneal SA. In measurements by Dr. Stern and Prof. Gatinel, the same lens gave more depth of field or more contrast depending on the combination of power, pupil and cornea.
  • In counseling: a monofocal lens with a modest intermediate gain, with no known cost in photic phenomena, and not a lens for reading.

What counts as “monofocal plus”

The category was born in 2019, with the first CE mark for a monofocal lens designed to slightly extend depth of focus. Many models have been introduced since, and they have no definition in a standard: ISO 11979-7 does not include such a category, and in the ESCRS functional classification they receive the label PARTIAL-RoF enhance (a range of 1.2–1.58 D at a threshold of 0.2 logMAR). Details in Classifying EDOF IOLs. In their review, Dr. Stern and Prof. Gatinel define these lenses as lenses that extend depth of focus but do not meet the EDOF criteria.

Three optical strategies

Three schematic graphs of the local power of the lens as a function of distance from its center: central add, negative SA and positive SA
Three ways to elongate the focus of a monofocal lens (schematic, not a measurement). The blue background marks the part of the lens that is used with a small photopic pupil or during the near reflex. With a central add and with a negative SA profile, the higher power is at the center; with positive SA it is in the periphery. Chart prepared for this page.
StrategyExampleWhat was measured on the benchClinical evidence base
Higher-order asphericity with power increasing toward the centerTecnis Eyhance (ICB00)An add of about 0.5 D in the central 2 mm and more negative SA than the monofocal model on the same platformThe broadest: randomized trials and meta-analyses
Controlled positive SARayOne EMVA moderate increase in primary positive SA; behavior similar to a spherical lensProspective series
Higher-order SA profile (“isofocal”)IsopureSubstantial negative SA; pupil dependenceLimited (one comparative study up to 2023)

Three things in the table matter. First, Zernike analysis of several models showed that SA of various orders was almost the only aberration that changed; in other words, these are “SA-modulating” lenses, and their behavior depends on the SA of the cornea. Second, the direction matters: when the higher power is at the center, the near reflex (miosis) exposes precisely the part that helps near vision; when it is in the periphery, miosis hides it. Third, comparing by trade name is misleading: the same “category” contains lenses with SA of opposite signs.

What the optical bench shows

Dr. Stern's measurements: power, pupil and cornea

In work presented at SAFIR 2024 (with Alain Saad and Prof. Damien Gatinel), the wavefront of the RayOne EMV and of a spherical lens from the same manufacturer was measured at powers of 10, 20 and 30 D, and propagated through 168 model eyes (21 corneas × 8 apertures). Depth of field was defined by the width of the MTF peak.

Three rows of color maps: the depth of field of the RayOne EMV, of a spherical lens and the difference between them, as a function of corneal SA and aperture
Depth of field (width of the MTF peak, in D) of the RayOne EMV (left), the RayOne Spheric (center) and the difference (right), at powers of 10 D (A), 20 D (B) and 30 D (C). Vertical axis: corneal SA; horizontal axis: aperture. The frame marks the SA range of normal corneas; above it are corneas after myopic LASIK, below it after hyperopic LASIK. From Dr. Stern's study (poster, SAFIR 2024).

The finding is consistent with the paper by Dr. Stern and Prof. Gatinel on monofocal lenses (Biomedical Optics Express, 2024): residual SA increases depth of field and tolerance to refractive error at the expense of contrast, and positive residual SA causes a myopic shift as the pupil dilates, so a system with negative residual SA is more stable between day and night. In AIOLsci simulations in corneas after refractive surgery, the lens with negative SA gave a higher peak after myopic LASIK, and the lens with positive SA after hyperopic LASIK. See Presbyopia-Correcting IOLs After LASIK.

The clinical evidence

SourceWhat was includedMain findings versus a standard monofocal
Wan et al., 2022 (meta-analysis)3 RCTs and 9 comparative studies; 680 versus 647 eyes; a single model (ICB00)Monocular UIVA better by 0.11 logMAR, binocular by 0.17; spectacle independence for intermediate OR 12.9; no difference in distance vision, contrast or photic phenomena
Fernández et al., 2025 (meta-analysis)31 studies, 8 of them RCTsDCIVA better by 0.11 and DCNVA by 0.12 logMAR; no difference in CDVA (high certainty); no difference in contrast or photic phenomena, but the certainty regarding positive dysphotopsia is moderate to low
Srinivasan et al., 2025 (meta-analysis of defocus curves)36 studies; 360 eyes with monofocal plusMean depth of focus 1.28 D versus 1.17 D, with no significant difference at any point on the curve
Fernández et al., 2023 (scoping review)Laboratory and clinical studies, 2020–2022No study met the ANSI criteria for EDOF; little clinical evidence for models other than the ICB00

How can an improvement of about one line at intermediate be reconciled with an almost identical defocus curve? The two pictures rest on different data: the meta-analyses of intermediate acuity mainly include direct comparisons of a single model against a monofocal, whereas the meta-analysis of defocus curves pools means from different studies which, according to its authors, were measured with non-uniform methods. The definitions also differ (UIVA or DCIVA, monocular or binocular, refractive target). What is consistent across all the sources: there is no appreciable cost to distance vision or contrast, and the gain is modest.

Positive SA: does it add depth or not?

In 2024, Kozhaya et al. induced SA with adaptive optics in pseudophakic eyes, and found that negative SA improved near vision and positive SA did not. With a monofocal plus lens, SA of −0.4 µm took 0.06 logMAR away from distance vision and added 0.09 logMAR to low-contrast near vision. Dr. Stern and Prof. Gatinel explained in a letter to the editor that the r² term in the Zernike polynomial for SA introduces defocus of the opposite sign, so that inducing positive SA without re-correcting the refraction shifts the center of the pupil toward hyperopia. According to them, both signs can extend the focus if the paraxial defocus is adjusted. In a prospective series of the EMV (50 eyes, emmetropic target, mean SE of −0.39 D), binocular vision was 0.2 logMAR or better over about 2 D (+1.00 to −1.25 D). The debate is covered in detail in Spherical Aberration: A Clinical Guide.

How to counsel the patient

  1. What to say: a monofocal lens with a modest gain in the intermediate range. For distance, like a monofocal; for reading, usually glasses. The improvement over a standard monofocal may be so subtle that the patient does not notice it.
  2. Photic phenomena: the literature has found no difference from a standard monofocal, so it is a reasonable choice for someone who is not willing to risk halos.
  3. Measure the pupil before dilation and obtain topography: with a central-add lens, a very small photopic pupil increases the myopic shift; with a positive-SA lens, a large pupil increases the effect.
  4. After corneal refractive surgery, choose the sign of the lens SA according to the SA of the cornea and not according to the name of the category.
  5. Mini-monovision (about −0.75 to −1.25 D in the non-dominant eye) increases the binocular range and preserves stereopsis better than full monovision; see Monovision.
  6. For someone who wants to read without glasses, the discussion is about EDOF or multifocal lenses, not monofocal plus. For patients: Enhanced Monofocal Lenses.

Frequently asked questions

Does a monofocal plus lens cause more halos than a monofocal lens?

The meta-analyses found no difference in photic phenomena or contrast sensitivity, but the certainty regarding positive dysphotopsia is moderate to low, and most of the data are on a single model. In counseling, it can be said that the profile is expected to be similar to that of a monofocal lens.

Do all monofocal plus lenses behave the same way?

No. Some add power at the center or negative SA, and others positive SA. Their response to the pupil and to corneal SA differs, and in an eye after LASIK the direction of the SA matters more than the name of the category.

References

  1. Fernández J, Ribeiro F, Burguera N, Rodríguez-Calvo-de-Mora M, Rodríguez-Vallejo M. Visual and patient-reported outcomes of an enhanced versus monofocal intraocular lenses in cataract surgery: a systematic review and meta-analysis. Eye. 2025;39(5):883-898. Link
  2. Wan KH, Au ACK, Kua WN, et al. Enhanced monofocal versus conventional monofocal intraocular lens in cataract surgery: a meta-analysis. J Refract Surg. 2022;38(8):538-546. Link
  3. Stern B, Gatinel D. Impact of pupil size and corneal spherical aberrations on the performance of monofocal intraocular lenses: an experimental model. Biomed Opt Express. 2024;15(11):6433-6448. Link
  4. Vega F, Millán MS, Gil MA, Garzón N. Optical performance of a monofocal intraocular lens designed to extend depth of focus. J Refract Surg. 2020;36(9):625-632. Link
  5. Alarcon A, Canovas C, Koopman B, Pande MV, Koch DD, Piers P. Optical bench evaluation of the effect of pupil size in new generation monofocal intraocular lenses. BMC Ophthalmol. 2023;23:112. Link
  6. Schmid R, Borkenstein AF. Analysis of higher order aberrations in recently developed wavefront-shaped IOLs. Graefes Arch Clin Exp Ophthalmol. 2022;260(2):609-620. Link
  7. Kozhaya K, Kenny PI, Esfandiari S, Wang L, Weikert MP, Koch DD. Effect of spherical aberration on visual acuity and depth of focus in pseudophakic eyes. J Cataract Refract Surg. 2024;50(1):24-29. Link
  8. Stern B, Gatinel D. Comment on: Impact of spherical aberration on visual quality and depth of focus. J Cataract Refract Surg. 2024;50(12):1297-1298. Link

Patient referrals and professional consultation

Physicians and optometrists are welcome to refer patients for a consultation on cataract, premium lenses and refractive surgery, or to contact Dr. Stern with a professional question.

Patient appointments at Hadassah Sharap: 02-677-8899 Direct contact details

The information on this page is intended for professionals and does not replace clinical judgment.