In brief
- The SA of the anterior cornea averages about +0.28 µm (Zernike, 6 mm), with a wide spread, and keratometry does not predict it. After myopic LASIK the mean is about +0.36 µm and after hyperopic LASIK about 0, with extremes of +1.02 and −0.58 µm.
- Spherical lenses add positive SA that increases with power; aspheric lenses are neutral or negative (down to about −0.27 µm).
- What determines the optics is the residual SA of the whole eye, and it depends on the pupil: SA increases with the fourth power of the pupil radius.
- Zero residual SA gives the highest contrast and the most stable focus between day and night; residual SA increases depth of field at the cost of contrast. Both signs extend the focus, in opposite directions.
- The practical choice: measure the corneal SA with topography, and match the sign of the lens SA to the goal: contrast, depth of field, or correcting a cornea after refractive surgery.
What spherical aberration is
In a system with SA, rays passing through the periphery of the pupil are focused at a different point from rays passing through the center. With positive SA the peripheral rays are refracted more strongly and focus in front of the central rays; with negative SA it is the reverse. In terms of power: positive SA means power that increases toward the periphery, and negative SA means power that decreases from the center to the periphery. Small numbers in microns represent a power that is not small: the review by Dr. Stern and Prof. Gatinel shows that −0.3 µm of SA (Zernike, 6 mm pupil) corresponds to a difference of about 1.8 D between the center of the pupil and its edge.
Two technical notes that matter when reading papers. First, the number is always defined for a specific diameter, usually 6 mm at the cornea (5.15 mm at the lens plane), and SA increases roughly with the fourth power of the radius: at a 3 mm pupil, about 1/16 of the 6 mm value remains. Second, the Zernike coefficient Z(4,0) includes, besides the r⁴ term, an r² term of opposite sign, that is, defocus. So “adding SA” in a model or a simulator also changes the refraction, unless it is corrected again.
Corneal SA in the population
- Normal cornea: in Wang et al. (228 eyes) the mean was +0.281 ± 0.086 µm, with a range of 0.058 to 0.545 µm, and 78.5% of eyes were between 0.20 and 0.40 µm. In the study by Beiko et al. (696 eyes) the mean was +0.274 ± 0.089 µm, and keratometry did not predict SA. The cornea is prolate (mean Q of about −0.2 to −0.3), but not enough to cancel the SA; on the relationship between Q and SA, see pupil size and SA in premium IOLs.
- After corneal refractive surgery (Bottos et al., 2011): after myopic treatment the mean rose to +0.36 ± 0.17 µm (range +0.04 to +1.02); after hyperopic treatment it fell to 0.00 ± 0.29 µm (range −0.58 to +0.63). The change was about +0.04 µm per diopter of myopic correction and about −0.19 µm per diopter of hyperopic correction.

The SA of the lens: three families
| Design | SA of the lens (6 mm at the cornea) | What it is good for | The price |
|---|---|---|---|
| Spherical | Positive, increasing with power (in a 20 D example: about +0.16 µm) | Corneas with high negative SA; a little extra depth of field with a small pupil | Low contrast with a large pupil in a normal cornea; myopic shift at night |
| Neutral aspheric | 0 | Corneas with low or mildly negative SA; more tolerant of decentration | Leaves the corneal SA as it is |
| Correcting aspheric | Negative, usually −0.18 to −0.27 µm | The highest contrast in a normal cornea, especially with a large pupil | Less depth of field and less tolerance of error; more sensitive to tilt and decentration |
The first correcting lens was designed to compensate partially for the average corneal SA. In the designers' models, it outperformed a spherical lens provided it was centered to within 0.4 mm and tilted by less than 7°. A meta-analysis of 43 randomized trials (2013) found that aspheric lenses did not improve acuity to a clinically meaningful degree (a difference of 0.01 logMAR), but did improve contrast sensitivity, especially in mesopic lighting; the results for reported quality of vision were inconsistent.
Residual SA: contrast versus depth of field
In the study by Dr. Stern and Prof. Gatinel (Biomedical Optics Express, 2024), three lenses from the same manufacturer (spherical, neutral and correcting) were measured in 168 model eyes. In each of them, peak MTF was highest when the corneal SA offset that of the lens. The more complete the offset, the better the contrast, but the narrower the depth of field and the range of tolerance to refractive error. On the other hand, positive residual SA causes a myopic shift when the pupil dilates, and a hyperopic shift when the pupil constricts with the near reflex; a system with negative residual SA is more stable.

Does only negative SA extend the focus?
In 2024, Kozhaya et al. induced SA with an adaptive optics simulator in pseudophakic eyes and found that negative SA improved intermediate and near vision and positive SA did not. Dr. Stern and Prof. Gatinel argued in a letter to the editor that the difference stems from the r² term of the Zernike polynomial, which shifted the center of the pupil toward hyperopia when positive SA was induced without correcting the refraction, and that both signs extend the focus if the paraxial defocus is adjusted. Holladay et al., for their part, emphasized the near reflex: the pupil constricts, and a system with negative SA, in which the center is stronger, benefits from it. On that point there is no disagreement.
Practical selection
| Corneal SA (6 mm) | Goal: maximum contrast | Goal: a little depth of field |
|---|---|---|
| Normal (about 0.2–0.4 µm) | A correcting lens, especially when the mesopic pupil is large | Neutral (and with a small pupil, spherical as well), accepting lower contrast at night |
| Low or mildly negative (after moderate hyperopic LASIK) | Neutral | Neutral; the negative corneal SA already adds depth |
| High negative (high hyperopic LASIK, PresbyLASIK) | Spherical | Consider a monofocal lens only: the cornea is already “EDOF” |
| High positive (after myopic LASIK) | The most correcting lens available; some residual SA will usually still remain | The corneal SA already extends the focus; beware of additional positive SA |
Two caveats. After myopic refractive surgery, even the most correcting lenses do not cancel the SA: according to Bottos, within the asphericity range of the lenses available at the time, only about 41% of the eyes studied would have had their SA fully offset or reduced. And among presbyopia-correcting lenses, many are themselves based on SA, so the corneal SA can cancel their effect or amplify it; see presbyopia-correcting IOLs after LASIK.
Take-home messages
- Topography or tomography with Zernike analysis for every candidate for an aspheric or premium lens, not only for a toric lens. Keratometry is not enough.
- Always ask “at what diameter?” when comparing SA values, and measure the pupil before dilation.
- Zero residual SA = contrast and stability; a little residual SA = depth of field and a wider “landing zone.”
- A correcting lens works only if it is centered; see tilt and decentration.
- In an eye that has had refractive surgery, the corneal SA is part of choosing the model, not a footnote. On reading the graphs: how to read optical bench data.
Frequently asked questions
Is it always worth canceling all of the corneal SA?
Not necessarily. Full cancellation gives the highest contrast and a stable focus between day and night, but it narrows the depth of field and the tolerance to a small refractive error. A patient with a small pupil, or one who prefers a little depth of field, may benefit from a small residual SA.
How do you know how much SA a patient's cornea has?
From topography or tomography with Zernike analysis of the anterior or total cornea, at a diameter of 6 mm. The biometer's keratometry does not predict SA, and after corneal refractive surgery the values vary widely between patients.
References
- Wang L, Dai E, Koch DD, Nathoo A. Optical aberrations of the human anterior cornea. J Cataract Refract Surg. 2003;29(8):1514-1521. Link
- Bottos KM, Leite MT, Aventura-Isidro M, et al. Corneal asphericity and spherical aberration after refractive surgery. J Cataract Refract Surg. 2011;37(6):1109-1115. Link
- Stern B, Gatinel D. Impact of pupil size and corneal spherical aberrations on the performance of monofocal intraocular lenses: an experimental model. Biomed Opt Express. 2024;15(11):6433-6448. Link
- Stern B, Gatinel D. Comment on: Impact of spherical aberration on visual quality and depth of focus. J Cataract Refract Surg. 2024;50(12):1297-1298. Link
- Kozhaya K, Kenny PI, Esfandiari S, Wang L, Weikert MP, Koch DD. Effect of spherical aberration on visual acuity and depth of focus in pseudophakic eyes. J Cataract Refract Surg. 2024;50(1):24-29. Link
- Holladay JT, Kozhaya K, Koch DD, Wang L. Impact of spherical aberration on visual quality and depth of focus. J Cataract Refract Surg. 2024;50(6):651-652. Link
- Schuster AK, Tesarz J, Vossmerbaeumer U. The impact on vision of aspheric to spherical monofocal intraocular lenses in cataract surgery: a systematic review with meta-analysis. Ophthalmology. 2013;120(11):2166-2175. Link
- Beiko GH, Haigis W, Steinmueller A. Distribution of corneal spherical aberration in a comprehensive ophthalmology practice and whether keratometry can predict aberration values. J Cataract Refract Surg. 2007;33(5):848-858. Link