Dr. Benjamin SternOphthalmology
For physicians and eye care professionals For physicians · Article

Chord Mu and Angle Alpha: What Affects Them, and Why It Matters for Multifocal Lenses

Halos and glare are among the common reasons for dissatisfaction after a multifocal lens, and a high chord mu value has been linked to them. A retrospective study of 2,415 cataract surgery candidates at Hadassah examined which biometric measures affect it, first and foremost pupil size.

In brief

  • Chord mu is the distance between the visual axis (represented by the corneal reflex, corneal vertex) and the pupil center. Angle alpha, expressed as a “chord,” is the distance between the visual axis and the iris center.
  • Holladay: when apparent chord mu is greater than 0.6 mm, halos and glare with a diffractive MFIOL are more likely.
  • In 2,415 eyes of cataract surgery candidates at Hadassah: mean chord mu 353 ± 207 µm, angle alpha (chord alpha) 491 ± 220 µm, and in 8.9% of eyes chord mu was greater than 600 µm.
  • Both measures are higher in short eyes, that is, in hyperopes.
  • Chord mu increases with pupil size, whereas angle alpha is stable. So measure without dilation and under standard lighting, or rely more on angle alpha.

What does this mean for patients?

Before a multifocal lens is implanted, one of the things that is checked is how far the center of the pupil is from the point through which the eye looks. The study showed that this measure increases when the pupil is dilated with drops, so it is important to measure it with a natural pupil; otherwise a suitable candidate could be ruled out by mistake. This is only one of the considerations in choosing the lens. General information: how to choose a multifocal lens.

Definitions: kappa, alpha and chord mu

Angle alpha is the angle between the visual axis and the optical axis, the line that passes through the optical centers of the cornea and the lens. The optical axis is hard to locate in the eye, which is not a perfectly aligned system. For years, therefore, angle kappa was used instead: the angle between the pupillary axis and the visual axis, which is easier to measure.

Biometers do not measure an angle but a distance in the corneal plane. The visual axis is represented by the reflection of the fixation light from the cornea (corneal vertex). The distance from it to the pupil center is chord mu, or more precisely apparent chord mu, because the pupil is measured through the cornea, which distorts the image. It is a vector, with a length and an axis, but the length is what matters. The distance to the iris center (the limbus) corresponds to angle alpha, and in the paper it is called chord alpha; on this page, “angle alpha” in microns means this chord. On the IOLMaster 700, chord mu appears in the Biometric values report, on the CW-Chord line (Chang-Waring chord). The device does not display chord alpha; in the study it was calculated from the iris-center coordinates that the device provides: √(Ix² + Iy²).

chord μαVisual axis – corneal reflexPupil centerIris center – limbuschord muAngle alpha
Front view (schematic): chord mu is the distance between the visual axis and the pupil center, and angle alpha is the distance between the visual axis and the iris center.

Why does this matter for multifocal lenses?

Multifocal lenses are built as concentric rings around the center of the IOL, on the assumption that the visual axis passes through the center. When chord mu or angle alpha is large, the visual axis falls outside the center of the lens, multifocality is compromised, and halos and glare appear. Holladay wrote that when apparent chord mu is higher than usual (above 0.6 mm, 600 µm), halos and glare with a diffractive MFIOL are more likely. Some papers prefer angle alpha, which is considered more stable before and after surgery. There is no agreed threshold for angle alpha; some authors have used 0.5 mm.

The evidence for these thresholds is limited. A 2025 review (Fernández et al.) concluded that there is no strong evidence to justify excluding a patient from a multifocal lens solely because of chord mu or chord alpha: an outlying value warrants further workup, and postoperative centration of the lens appears to matter more.

The question the study set out to answer: are these measures independent, or are they related to other biometric parameters, so that at-risk patients can be identified in advance?

The study: who is at risk of a high chord mu?

Methods

A retrospective study that included 2,767 cataract surgery candidates over age 50 who were examined at Hadassah Ein Kerem from 2018 to 2020. Biometry was performed with the IOLMaster 700 (swept-source OCT). Per department protocol, most patients received dilating drops (tropicamide 0.5% and phenylephrine 10%) before the measurement, and mean pupil size was 4.93 ± 2.02 mm. When the patient was phakic in both eyes, one eye was selected at random. A total of 352 patients were excluded: 92 because of missing demographic data, 76 because of previous surgery (refractive or vitrectomy), and 184 because one of the parameters could not be measured. This left 2,415 eyes (87%). Mean age was 72.5 ± 9.1 years (range 50.3–97.7), and 54.9% were women.

Findings

Box plot of chord mu by four axial length groups
Chord mu (microns) by axial length: below 22 mm, 22–24.5 mm, 24.5–26 mm and above 26 mm.
Box plot of angle alpha by four axial length groups
Angle alpha (microns) in the same groups. Both measures decrease as the eye gets longer.

The explanation: when the pupil dilates, the pupil center shifts inferiorly and temporally, while the iris center, as expected, stays where it is. In other words, the pupil does not dilate symmetrically, and its inferotemporal part dilates more.

Scatter plot of chord mu against pupil size, with a threshold line at 600 microns and a line at a 4 mm pupil
Chord mu (microns) against pupil size (mm) in 2,415 eyes. The horizontal line marks 600 µm, and the vertical line a pupil of 4 mm. Above 4 mm there are more eyes above the threshold.

The values by pupil size group, as published in the paper (mean ± standard deviation, in mm):

Pupil size (mm)EyesChord muAngle alpha (chord alpha)
<2.51600.28 ± 0.140.48 ± 0.18
2.5–3.56580.32 ± 0.180.49 ± 0.17
3.5–4.54520.34 ± 0.240.50 ± 0.22
4.5–5.51920.40 ± 0.260.50 ± 0.22
5.5–6.52440.39 ± 0.250.48 ± 0.19
6.5–7.53420.37 ± 0.200.49 ± 0.19
7.5–8.52930.39 ± 0.210.48 ± 0.21
>8.5740.47 ± 0.360.58 ± 0.41

Overall, 215 eyes (8.9%) had a chord mu greater than 0.6 mm, and 98 (4.1%) were above 0.767 mm (the mean plus two standard deviations). In the analysis presented at the conference, with a threshold of 600 µm or more (226 eyes, 9.4%), the rate was 6.7% with a pupil smaller than 4 mm and 11.7% with a pupil of 4 mm or more.

Study limitations

Practical implications

The study was carried out in collaboration with Prof. Itay Chowers (Department of Ophthalmology, Hadassah) and Dr. Hadas Ben-Eli (Department of Optometry and Vision Science, Hadassah Academic College), was presented at the 2021 conference of the Israeli Ophthalmological Society, and was published: Stern B, Chowers I, Ben-Eli H. Effect of mydriasis on chord mu value in cataract surgery candidates. Eur J Ophthalmol. 2024;34(3):759–765 (published online in 2023). Full paper. The full list of publications is on the home page.

Frequently asked questions

Above what chord mu value should you be cautious about a multifocal lens?

Holladay wrote that when apparent chord mu is greater than 0.6 mm (600 microns), halos and glare with a diffractive lens are more likely. There is no agreed threshold for angle alpha. A 2025 review notes that the evidence for these thresholds is limited, and that an outlying value warrants further workup rather than automatic exclusion.

Can chord mu be measured with a dilated pupil?

Preferably not. In the study, chord mu increased with pupil size: from a mean of 0.28 mm with a pupil smaller than 2.5 mm to 0.39 mm with a pupil of 7.5–8.5 mm, an increase of 39%. Angle alpha was not affected by pupil size, so it can serve as an alternative when biometry was done after dilation.

Where do you find chord mu on the IOLMaster 700?

In the Biometric values report, on the CW-Chord line (Chang-Waring chord), which shows the length and the axis. The length is the important value. The device does not display chord alpha; it can be calculated from the iris-center coordinates (Ix, Iy).

References

  1. Stern B, Chowers I, Ben-Eli H. Effect of mydriasis on chord mu value in cataract surgery candidates. Eur J Ophthalmol. 2024;34(3):759-765. Link
  2. Holladay JT. Apparent chord mu and actual chord mu and their clinical value. J Cataract Refract Surg. 2019;45(8):1198-1199. Link
  3. Chang DH, Waring GO 4th. The subject-fixated coaxially sighted corneal light reflex: a clinical marker for centration of refractive treatments and devices. Am J Ophthalmol. 2014;158(5):863-874. Link
  4. Shouchane-Blum K, Reitblat O, Dadon J, Bahar I, Sella R. Evaluating changes in apparent chord mu after pharmacological pupil dilatation. Ophthalmic Res. 2023;66(1):921-927. Link
  5. Fernández J, Ribeiro F, Burguera N, Burguera-Giménez N, Rodríguez-Vallejo M. Replacing theories with evidence around the axes of the eye in intraocular lens selection: a review for the clinician. Ophthalmol Ther. 2025;14(3):471-487. Link

Patient referrals and professional consultation

Physicians and optometrists are welcome to refer patients for a consultation on cataract, premium lenses and refractive surgery, or to contact Dr. Stern with a professional question.

Patient appointments at Hadassah Sharap: 02-677-8899 Direct contact details

The information on this page is intended for professionals and does not replace clinical judgment.