In brief
- After routine surgery, a few degrees of tilt and a few tenths of a millimeter of decentration are the rule, not the exception. The natural lens is usually tilted about 5° inferotemporally, and the IOL “inherits” this tilt.
- The number depends on the reference axis: relative to the pupillary axis (Purkinje) mean tilt is less than 2.6°, and relative to the corneal topographic axis (AS-OCT) it is about 4°–5°.
- Sensitivity to decentration depends on the design: lenses with strongly negative SA and premium lenses are more sensitive than spherical or neutral lenses. With an aberration-correcting aspheric lens the advantage disappears at a decentration of about 0.5 mm.
- With a toric lens, each degree of off-axis rotation leaves about 3.3% of the cylinder; at 30° there is no net correction.
- The natural lens predicts the position of the IOL: preoperative tilt and decentration are the strongest predictors.
How much tilt and decentration occur in practice
| Study | Method and reference axis | Tilt | Decentration |
|---|---|---|---|
| de Castro and colleagues, 2007 (21 eyes with an IOL) | Purkinje and Scheimpflug, relative to the pupillary axis | Mean less than 2.6° | Mean less than 0.4 mm |
| Kimura and colleagues, 2017 (59 eyes with an IOL) | AS-OCT (CASIA2), relative to the corneal topographic axis | 4.3°–4.7° inferotemporally | 0.05–0.08 mm temporally |
| Chen and colleagues, 2021 (1,097 natural lenses) | AS-OCT before cataract surgery | Mean 5.16° inferotemporally; 10.9% above 7° | Mean 0.22 mm temporally; 8.1% above 0.4 mm |
Two conclusions. First, numbers cannot be compared between studies without knowing the reference axis: a 2020 review found that there is no uniform reference axis, and that comparison between methods is limited. Second, the position of the IOL is strongly related to the position of the natural lens (correlation coefficient of 0.8 or higher in Kimura), and both are tilted in the inferotemporal direction, with mirror symmetry between the two eyes. The review by Ashena and colleagues concludes that tilt of up to 2°–3° and decentration of 0.2–0.3 mm are common and are not clinically noticeable, with any type of lens.


Who is at risk
- The natural lens: preoperative tilt and decentration of the lens are the strongest predictors of significant tilt and decentration of the IOL (in a study of eyes after vitrectomy, an area under the curve of about 0.8). In the natural lens, greater tilt was found in short eyes and with thick lenses.
- The surgery and the lens: incomplete overlap of the capsulorhexis on the optic, and in one study a hydrophilic lens as well, increased the risk. Greater decentration was measured with three-piece lenses than with single-piece lenses. Lenses with scleral fixation are tilted more often than lenses in the bag.
- Preoperative prediction: models based on biometry and AS-OCT predicted lens position to within about 0.3 mm for decentration and 1.5° for tilt (95% confidence interval).
In such studies, “significant tilt” was defined as 7° or more and “significant decentration” as 0.4 mm or more. These are thresholds chosen for the study, not agreed clinical thresholds.
How much each design tolerates
| Design | What happens with tilt or decentration | Thresholds proposed in the literature |
|---|---|---|
| Spherical or neutral aspheric | High tolerance; with a neutral lens there is no SA that shifts with the lens | — |
| Aspheric with negative SA | Decentration of the correcting SA induces coma and astigmatism, and the contrast advantage disappears | In the original design: preferable to a spherical lens if centered within 0.4 mm and tilted less than 7°; according to the review, the advantage is lost above about 0.5 mm |
| Toric | Rotation leaves cylinder; tilt and decentration add uncertainty to the correction | About 3.3% of the cylinder per degree; 30° = no net correction |
| Multifocal and EDOF | The distribution of light between the foci changes; contrast is reduced; sometimes more photic phenomena | With one multifocal lens, an association with lower distance acuity was found from a decentration of 0.4 mm; with other lenses no association was found |

A 2026 systematic review of 74 optical bench studies arrived at the same picture: monofocal lenses with negative SA were affected by decentration more than spherical lenses; multifocal and EDOF lenses were more sensitive; and toric lenses were affected especially when decentration was combined with axis misalignment. On the other hand, some designs were found to be robust: on a bench that tested decentration of 0.2–0.4 mm and tilt of 2°–4°, the expected effect on acuity with a 3 mm pupil was negligible, and it was actually the refractive EDOF lens that was more sensitive to decentration than the diffractive trifocal lens. The generalization “premium = sensitive” is true on average, but not for every model. In general, decentration has a greater effect on acuity than tilt, and the internal coma it induces increases with pupil size.

The visual axis, the pupil and chord mu
A lens centered in the bag is not necessarily centered on the visual axis. With multifocal lenses, whose rings are concentric around the center of the lens, a large chord mu (the distance between the corneal light reflex and the pupil center) has been associated with halos and glare, and Holladay proposed a threshold of 0.6 mm. In Dr. Stern's study of cataract surgery candidates at Hadassah, mean chord mu was about 0.35 mm, and 8.9% of eyes exceeded 0.6 mm; the value increased with pupil dilation, because the pupil center shifts inferotemporally, so it should be measured without drops. A 2025 review found no strong evidence for excluding a patient on the basis of chord mu alone, and the actual centration after surgery appears to matter more. Details in Chord Mu and Angle Alpha. A large angle kappa has also been associated with negative dysphotopsia; see Dysphotopsia.
In practice
- Before surgery: if you have an AS-OCT or a biometer that measures the position of the natural lens, look at its tilt and decentration. In a lecture, Dr. Stern raised the question of whether, in an eye with marked tilt of the natural lens, it is better to choose a lens with neutral SA or a spherical lens, which tolerates decentration better. This is an open question, and it rests on bench data.
- With a multifocal lens: measure chord mu without dilation, and consider the design: some models are more robust.
- During surgery: a round, centered capsulorhexis that overlaps the optic over 360°, and with a toric lens precise alignment and a check for rotation after surgery.
- After surgery, when the outcome is unexplained: check the position on AS-OCT relative to the topographic axis, and internal aberrometry (coma). Clinically significant decentration of a premium lens can justify repositioning. On refixation: IOL Fixation Techniques.
Frequently asked questions
At what amount of decentration should repositioning of a premium lens be considered?
There is no agreed threshold. The literature mentions 0.4 to 0.5 mm as the point at which aberration-correcting aspheric lenses lose their advantage, and in studies of multifocal lenses the results were not uniform. The decision rests on the complaint, on the AS-OCT finding relative to the topographic axis and on internal aberrometry.
Why do tilt figures differ so much between papers?
Because they are measured relative to different axes and with different methods: relative to the pupillary axis with Purkinje, mean tilt is less than 2.6 degrees, and relative to the corneal topographic axis with AS-OCT it is about 4 to 5 degrees. Compare only between studies that use the same reference axis.
References
- Ashena Z, Maqsood S, Ahmed SN, Nanavaty MA. Effect of intraocular lens tilt and decentration on visual acuity, dysphotopsia and wavefront aberrations. Vision (Basel). 2020;4(3):41. Link
- Kimura S, Morizane Y, Shiode Y, et al. Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography. PLoS One. 2017;12(9):e0184066. Link
- Chen X, Gu X, Wang W, et al. Distributions of crystalline lens tilt and decentration and associated factors in age-related cataract. J Cataract Refract Surg. 2021;47(10):1296-1301. Link
- de Castro A, Rosales P, Marcos S. Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging. Validation study. J Cataract Refract Surg. 2007;33(3):418-429. Link
- Zhang J, Han X, Zhang M, et al. Predicting the risk of clinically significant intraocular lens tilt and decentration in vitrectomized eyes. J Cataract Refract Surg. 2022;48(11):1318-1324. Link
- Cuellar F, Vega F, Madrid D, Alfonso JF, Millan MS. Optical and simulated visual outcomes of two presbyopia-correcting intraocular lenses tested in clinically relevant decentration and tilt conditions. Biomed Opt Express. 2025;16(12):5063-5077. Link
- Stern B, Chowers I, Ben-Eli H. Effect of mydriasis on chord mu value in cataract surgery candidates. Eur J Ophthalmol. 2024;34(3):759-765. Link
- Holladay JT, Piers PA, Koranyi G, van der Mooren M, Norrby NE. A new intraocular lens design to reduce spherical aberration of pseudophakic eyes. J Refract Surg. 2002;18(6):683-691. Link