In brief
- A small-aperture lens is a monofocal lens with an opaque mask and a central hole: in the IC-8 the mask is 3.23 mm in diameter and the aperture is 1.36 mm. The pinhole shrinks the blur circle and extends depth of focus.
- The price is light: less light reaches the retina, and vision in dim light and mesopic contrast may suffer. With a large pupil, light bypasses the mask and the pinhole effect weakens.
- In the large series the lens was implanted in the non-dominant eye with a mildly myopic target, and gave good distance and intermediate vision and fair near vision. All the evidence consists of case series, most of them with ties to the manufacturer.
- A real advantage in irregular corneas (stable keratoconus, RK, corneal transplant, scar): the pinhole filters out the corneal aberrations.
- Dr. Stern believes that, because of the reduction in retinal illuminance, this is not a good option for routine presbyopia correction.
The principle
A small aperture blocks the peripheral rays, which are also the ones most sensitive to aberrations. The blur circle of an out-of-focus point becomes smaller, so the same image stays sharp over a wider range of distances. In photography, a small aperture is compensated for with a long exposure time; in the eye that is not possible, and so, as Dr. Stern and Prof. Gatinel explain in their review, a higher f-number means less light, and this is the main problem with the technology. An aperture that is too small also degrades sharpness, because of diffraction.


The devices
| Device | What it is | Main use |
|---|---|---|
| IC-8 (now IC-8 Apthera) | A one-piece hydrophobic lens for the bag, with a 3.23 mm mask and a 1.36 mm aperture | Presbyopia in cataract surgery, usually in the non-dominant eye; irregular corneas. FDA-approved in July 2022, for eyes with up to 1.50 D of corneal astigmatism |
| XtraFocus | A black add-on lens with a pinhole, for the sulcus or the bag | Irregular corneas in pseudophakic eyes; iris defects (CE mark in 2016) |
| KAMRA | A corneal inlay with a pinhole | Presbyopia in a phakic eye; in the FDA trial, 8.7% of the inlays were removed within 3 years |
The clinical evidence
- The large series (Dick et al., 2017): 105 patients, an IC-8 in one eye and an aspheric monofocal lens in the other. After 6 months, in the IC-8 eye: uncorrected acuity of 20/23 at distance, 20/24 at intermediate and 20/30 at near; 99%, 95% and 79% reached 20/32 or better binocularly at distance, intermediate and near. With a target of −0.75 D, the near range was extended by about one additional diopter without loss of distance vision, and intermediate and near vision were maintained with up to 1.5 D of residual astigmatism. 95.9% said they would have the surgery again.
- Systematic review (2022): 22 studies, 460 eyes, all of them case series or case reports, with ties to the manufacturer reported in 12. The mean target in the non-dominant eye was about −0.6 D. Photic phenomena were reported as low in most studies.
- Bilateral implantation: in a small series, implantation in both eyes gave a wider range and better intermediate and near vision, but satisfaction was higher and halos were fewer with implantation in one eye. In another series, satisfaction was similar with the two approaches.
- Contrast: mesopic contrast sensitivity was lower than with a monofocal lens, but within the normative range.
Irregular corneas
In a series of 17 eyes with highly irregular corneas (non-advanced keratoconus, corneal transplant, RK, traumatic scar), corrected acuity improved from 0.37 to 0.19 logMAR. Power calculation in these eyes is less predictable: in another series of 17 eyes, the mean postoperative SE was −1.22 D. Here the small aperture is not only a tool for presbyopia but a way to filter out the corneal aberrations. In his lectures, Dr. Stern also points out the flip side: a patient with a very small natural pupil and a monofocal lens gets a similar effect “for free.” See keratoconus and multifocal IOL selection.
Limitations
- Dim light. Less light reaches the retina; patients sometimes describe dimmed vision. With the add-on lens, patients are told in advance that dimming may occur and may lead to removal of the lens.
- Large pupil. When the mesopic pupil is large, light bypasses the mask; halos, double vision and fluctuating vision have been linked to a large pupil. The review mentions a mesopic pupil smaller than 6 mm as a patient selection criterion.
- The retina. In the review by Dr. Stern and Prof. Gatinel, lenses that reduce illuminance are considered contraindicated in any condition that impairs retinal sensitivity. For the IC-8, the mask was reported not to interfere with retinal examination, routine tests or retinal treatment, and some patients with macular disease were reported as satisfied; the add-on lens has to be removed before retinal laser or surgery, and a full retinal exam with scleral depression is required before it is implanted.
- YAG for the posterior capsule. A hit on the dark ring, which contains carbon particles, causes far greater damage than a hit on the clear zone, and in a case report the damage required IOL exchange. The recommendations are low energy, a posterior offset of the focus, and firing within the aperture or outside the mask.
Who is a good candidate
| Consideration | More suitable | Less suitable |
|---|---|---|
| Cornea | Irregularity or high HOAs with a clear center; after RK or a transplant; corneal astigmatism up to 1.5 D | A regular cornea when there are alternatives with less light loss |
| Pupil | Small to medium mesopic pupil | Large mesopic pupil |
| Retina and optic nerve | Healthy retina | A disease that impairs light sensitivity or that may progress |
| Lifestyle | Willing to accept less bright vision in dim light | A great deal of night driving and reliance on vision in dim lighting |
| Strategy | One eye (the non-dominant eye), mildly myopic target | — |
Dr. Stern's position
Dr. Stern explains in his lectures that the pinhole does increase depth of focus and reduce the effect of aberrations, but because of the reduction in retinal illuminance, in his view it is not a good option for routine presbyopia correction. In his review with Prof. Gatinel, the lens is described as particularly suited to irregular corneas. On the alternatives, see classifying EDOF IOLs, monofocal plus IOLs and the review of presbyopia correction.
Frequently asked questions
Can a pinhole lens be implanted in both eyes?
Yes, and it has been done in small series. Bilateral implantation gave a wider range and better near vision, but in one of the series satisfaction was lower and halos were more frequent than with implantation in one eye. In most studies the lens was implanted in the non-dominant eye only.
How is YAG of the posterior capsule performed in an eye with a pinhole lens?
With the lowest possible energy, with a posterior offset of the focus, and firing within the central aperture or outside the mask. A hit on the dark ring, which contains carbon, causes major damage to the lens, and in one case report it required exchange of the lens.
References
- Stern B, Gatinel D. Presbyopia correction in lens replacement surgery: a review. Clin Exp Ophthalmol. 2025;53(6):668-681. Link
- Dick HB, Piovella M, Vukich J, Vilupuru S, Lin L. Prospective multicenter trial of a small-aperture intraocular lens in cataract surgery. J Cataract Refract Surg. 2017;43(7):956-968. Link
- Sánchez-González JM, Sánchez-González MC, De-Hita-Cantalejo C, Ballesteros-Sánchez A. Small aperture IC-8 extended-depth-of-focus intraocular lens in cataract surgery: a systematic review. J Clin Med. 2022;11(16):4654. Link
- Ang RET, Araneta MMQ, Cruz EM. Review of surgical devices using small aperture optics. Taiwan J Ophthalmol. 2022;12(3):282-294. Link
- Shajari M, Mackert MJ, Langer J, et al. Safety and efficacy of a small-aperture capsular bag-fixated intraocular lens in eyes with severe corneal irregularities. J Cataract Refract Surg. 2020;46(2):188-192. Link
- Dick HB, Elling M, Schultz T. Binocular and monocular implantation of small-aperture intraocular lenses in cataract surgery. J Refract Surg. 2018;34(9):629-631. Link
- Borkenstein AF, Kormilina TK, Fitzek H, et al. Incorrectly focused neodymium:yttrium–aluminum-garnet (Nd:YAG) laser beam leads to massive destructive effects in small-aperture (pinhole) intraocular lenses. Ophthalmol Ther. 2024;13(10):2745-2758. Link
- Tay C, Mehta JS. Presbyopia intraocular lens in aberrated corneas. Taiwan J Ophthalmol. 2025;15(4):559-571. Link